Moving Fast - Solar Uptake on New Homes

 


New data provided by the Microgeneration Certification Scheme (MCS) shows that the proportion of new homes built in England that come with solar PV has more than doubled in the last 12 months.

In the last quarter of 2023 it was estimated that 13% of new homes that completed construction had solar PV fitted by the developer.  This figure has risen to 29% in the most recent quarter and will continue to grow as housebuilders in England further transition to the 2021 version of Part L of the Building Regulations.

As the number of new homes with solar PV built by private developers has increased, the average installed power (kWp) per new build installation is falling.  

Prior to the new Building Regulations coming into force, solar on new homes was driven by either local planning requirements or fitted by self-builders as a personal preference.  Self-builders would size a system for a cost-effective contribution towards their own energy requirements.  Solar to meet a planning condition was on a site-wide basis and tended to be concentrated onto a few homes on the development to meet the condition in the most cost-effective way.  

By contrast the new Building Regulations apply individually to each plot but once the required energy performance of the building is met, developers generally see little reason to extend a PV system further - resulting in generally smaller PV installations.  The effect of this can be seen in the kWp/install column where the average has reduced over the period from 3.8kWp per installation to 2.8kWp.

Also worth noting is that solar on new buildings has risen from being 19% of MCS certified solar installations in England to 34% over the period.  As already mentioned, this transition has further to run and I predict that by the end of 2025, new build solar will account for at least 50% of MCS solar installations in the UK.


Notes on the Analysis

The number of new build MCS solar PV installations in the quarter was expressed as a proportion of new build housing completions in the same period to arrive at a percentage of new homes built with solar PV.

When registering a new solar PV installation with the MCS, the installer must tick a box to say whether the installation is on a new building.  The brilliant, publicly available MCS data dashboard does not currently allow users to filter the data on this basis, but the team at MCS responded to a request from Solar Energy UK and kindly provided us with the data.  I hope this functionality can be added in future.

The MCS certificate is issued only when the system is commissioned, which occurs after second fix.  This creates the potential for a timing difference between the MCS data and the data based on practical completion of the building (which may come a few weeks later).  The error this creates is mitigated against by aggregating to quarterly data.

It is also worth mentioning that it was not possible to split the MCS new build data into residential and commercial installations, so I have had to assume that the total is all residential, which will result in an over-estimate, but one that reduces as the number of new build homes with solar grows.  On the other hand not all solar installations will run through the MCS so this mitigates the over-estimate, as does focusing on the number of installations rather than the installed power (commercial solar tends to be larger systems in lower number).

Data for housebuilding completions is taken from this ONS dataset, which is quarterly, and only available up to Q2 2024.  The dataset was extended by one quarter by reference to this NHBC data which was used to scale the figure for Q2 to Q3.

















Friday, 26 January 2024

The Future Homes Standard Unwrapped

A Review of The FHS 'Wrapper' for the Home Energy Model 





The Future Homes Standard (FHS) consultation includes proposals for a wholesale revision to the underpinning calculation method by which the energy efficiency of new homes is evaluated.

I have already written about the Home Energy Model (HEM) in an earlier blog.  It is planned that this will replace the Standard Assessment Protocol (SAP) currently in use by Energy Assessors to calculate whether a new home design specification meets building regulations.  An FHS version of the Home Energy Model will be used to demonstrate compliance with the building regulations, by preloading the Home Energy Model calculation with a set of assumptions and inputs and defining the outputs it needs to provide, collectively called a 'Wrapper' for the HEM.





The consultation document on the Future Homes Standard wrapper can be found here.

In this blog I go through the most significant changes the wrapper introduces compared to the current version of SAP.


Occupancy

When a new home is built you probably don't know how many people will live in it and even if you do it will change over time, so calculations for building regulations require a standard occupancy.

The number of occupants is an important factor - affecting the amount of energy used for lighting, appliances and hot water use.

In SAP the standard occupancy was taken to be a function of the total floor area of the building, but for the FHS this will change to be driven by the number of bedrooms, apart from 1 bedroom dwellings which will have an occupancy driven by floor area.

In the graph above the dots show data from a national survey and indicate that SAP 10 occupancy (wide yellow line) is not a good match.  the coloured horizontal lines show the new occupancy level based on the number of bedrooms.  

A higher occupancy will increase the hot water demand (although this is offset by other changes, see below), and electricity demand for lighting and appliances.

Hot Water Demand

As in SAP 10.2, hot water demand is driven by occupancy, but demand per occupant is lowered based on new evidence from a 2021-22 study of 45,000 combi boilers in UK homes, which suggests that measures taken to reduce hot water use (for example low flow taps and shower heads) have had an effect on hot water use.




For contrast typical consumption in SAP 10.2 is 120 litres per day for a two person household and 160 litres a day for a three person household.  This reduction of nearly 20% will be offset by the higher occupancy for three and four bed homes.


Weather

The FHS standard is consulting on the use of regional weather data.  Historically housebuilders have been against this as it means they cannot build the same house all round the country (or rather they can but would need to meet the regulations in the most arduous location and therefore over-provide in others).

Another possible change is to use 'future' weather files based on Met Office climate projections relating to the assumed use period of the standard (2025-29).  


Electricity Demand

The wrapper also contains assumptions on electricity use for lighting and other appliances (dishwasher, tumble dryer, fridge, freezer and electronic goods).  

The FHS wrapper has to support the 30 minute time resolution of the Home Energy Model so both lighting and appliance electrical use has been split into daily profiles.  For now, these profiles are aggregated and averaged whereas in real life electricity demand is more 'peaky' with kettles being boiled for only a few minutes and freezers cycling on and off.  This smoothing will over-state self consumption of electricity for solar PV.

Compared to SAP 10.2 the demand for lighting is increased, reflecting the fact that homes have more and brighter lighting than in the past, although the efficiency gains from LED bulbs more than offsets this.


Emissions Factors



In the FHS, the emissions associated with mains electricity has fallen substantially from the value used in SAP 10.2, reflecting the decarbonisation of the generation mix providing UK power, and also a change in approach to predict the carbon intensity of the grid for the time the standard is in use rather than fixing it at the consultation value.

The big difference in the emissions factor for renewable generation is due to an 'accounting change'.  As explained in this document Fuel factors within the Home Energy Model: FHS assessment, the emissions factor for on-site generated is deducted from the emissions factor for grid electricity when calculating a reduction in dwelling emissions and primary energy.

This differs from SAP 10.2 where the onsite generated energy was a negative value and was multiplied by the renewable emissions factor to get a saving to take away from the total emissions or primary energy for the period.

A key factor to note is that solar generation exported to the grid produces the same benefit to carbon emissions and primary energy as solar generation used in the home.  The logic is that this exported unit of electricity is preventing the need to generate electricity at the grid factor and the benefit accrues to the dwelling.  This is in stark contrast to Scottish building regulations which since the 2023 revision have deliberately excluded the benefits of exported energy from contributing to the assessment of the dwelling performance.

Another feature of this approach is that energy storage in batteries produces no benefit on emissions or primary energy scores.  In fact the addition of a round-trip efficiency to energy stored in a battery for later use actually reduces the benefit of battery storage compared to export.  This will remain the case until the model can take account of the fact that grid emissions and primary energy varies during the day and a strategy of avoiding export by storing surplus solar generation for use in the evening will not only reduce energy bills but also result in a net reduction in carbon emissions and primary energy use because renewable energy is generally less of the grid mix at this time of day .


Conclusions

The addition of a time of day value for grid emissions and primary energy would be a welcome addition to the FHS Home Energy Model, but apart from this omission, the changes introduced compared to SAP 10.2 look benign from the point of view of the solar industry.








  

Tuesday, 2 January 2024

The "Home Energy Model" - The Artist Formerly Known as SAP


 



Alongside its consultation on the Future Homes Standard building regulations, the government has revealed sweeping changes to the calculation underpinning Part L of the building regulations (Conservation of Fuel and Power), and launched a consultation on the new approach.

The StandardAssessment Procedure (SAP) has been the government approved methodology to estimate the energy performance of homes in the UK since 1993, a time when it was felt to be important that the method be simple enough to be completed with pen and paper and calculator. 

Inevitably, computer software emerged to make the job of energy assessors more convenient.  Provided by third party companies, these applications needed to be checked by the Building Research Establishment (BRE), the body responsible for the development of SAP, before they could be used to demonstrate compliance with building regulations.

Over subsequent versions of SAP issued in 1998, 2001, 2005, 2009, 2012 and 2022 the complexity of the model increased.  Building elements were dealt with in more sophisticated ways to improve the accuracy of the model (for example the treatment of junctions in thermal insulation or - a personal favourite – an improved treatment of the performance of solar thermal systems in 2005).  New technologies were more widely adopted in construction and needed to be added (for example battery storage in 2022).

SAP's Growing Pains

Shortcomings of this approach had begun to emerge over time but were brought into sharp focus by the 2022 implementation.  Developers found themselves struggling to work out how to build new homes that complied with the new building regulations already in force even as the third-party software was unavailable due to delays in the certification process.

Another reason for a wholesale review of the model, flagged by the Climate Change Committee, was the emergence of key technologies that couldn’t be easily or accurately added to the existing framework in a timely way:

  • Solar PV and self-consumption of generated electricity
  • Battery storage of electricity
  • Solar PV diverters
  • Time of use energy tariffs
  • Smart energy controls – timing the use of energy to coincide with cheap tariffs and the availability of renewable energy.

The SAP model was based on a monthly time resolution.  This meant that the impact of new technologies had to be demonstrated in real life studies and an average performance across multiple households derived before a simplified month by month impact could be added to the model.

A case in point was the introduction of battery storage in the 2022 version.  Data was scarce because the technology was relatively new.  A simplified average performance that linked installed solar capacity, total energy use and battery storage capacity was derived by applying a line of best fit to the available data.  This formula was incorporated into the monthly SAP model.  No data was available on homes that combined battery storage with solar PV diverters, so SAP only allowed one of the technologies to be used at a time.

 

 A New Approach

The government is consulting on a fundamental re-working of the model.  It’s such a big change that SAP has been dropped in favour of a new name ‘The Home Energy Model’.  Changes include:

  • The model will be available as a cloud-based software ‘core engine’, with the source code published on GitHub
  • ‘Wrappers’ will be published for different applications – comprising different starting assumptions as inputs which will then feed into the same core engine.  The first wrapper to be published will be for the 2025 building regulations, followed by a wrapper for the generation of Energy Performance Certificates (EPCs) for existing homes.
  • The software runs on a 30-minute time resolution, allowing better modelling of smart technologies such as solar, battery storage and time-of-use energy tariffs
  • An updated solar PV generation calculation is based on the hourly methodology in BS EN 15316-4-3:2017, which includes the effect of ventilation on the rear of the panels.

Impact on Solar

 The solar industry should welcome the change from SAP to the new Home Energy Model.

The move to cloud-based software brings the approach up to date.  The separation of a core engine, based on best available building physics modelling, from the ‘wrappers’ which clearly surface the assumptions and inputs into the model for specific applications such as building regulations or EPCs makes it much easier to interrogate how the ‘black box’ is working.

The change to a half-hour resolution better supports enabling technologies that work with solar PV – battery storage, smart energy controls and hot water from PV fed immersion heaters.  This will further cement the position of solar PV as a normal part of any new home built in the UK.

The change to the hourly methodology for solar generation needs to be carefully assessed, I will be writing about this in my next blog. 

 

 

 

 

 

 

 

Thursday, 25 August 2022

New Homes to Have Charge Points for Electric Vehicles as Standard


Housebuilders in England will soon be fitting EV chargers to new homes, how do the new rules work and what is happening in the other home nations?

How the New Rules Work in England

In December 2021, the government published Approved Document S, a new part of the Building Regulations that apply in England.  The new regulations require developers to fit Electric Vehicle (EV) charging points when building a new home.

Where a new residential building has a parking space then EV charge points must be provided - one per dwelling or one per parking space, whichever is the lower.

So for a new house that has its own parking space at least one EV charger must be installed.

For an apartment block with a car park for residents the number of EV chargers provided would be the number of dwellings in the block, (unless the number of spaces in the car park was less than the number of dwellings).

Exemptions exist if the developer can demonstrate that fitting so many EV chargers would overload the electricity supply.  If grid reinforcement costs exceed £3,600 per charge point then the developer can install less EV charging - up to the number that would cause grid reinforcement costs to exceed £3,600 (excluding VAT) per charge point.  Any unserved parking spaces must instead be provided with a cable route from the power supply to the parking space to aid future installation (but not a cable).

Each electric vehicle charge point needs to have a minimum nominal rated output of 7kW, be untethered (have a socket rather than a lead), and have an indicator to show the equipment’s charging status.

The approved document took effect on 15 June 2022. It does not apply to new buildings submitted for planning before that date, unless the plot build starts after 15 June 2023. 

What this means in practice is that any new building sites where planning permission was applied for after June 2022 will need to meet the new requirements.  Building sites that had already applied for planning permission before June 2022 will need to transition individual plots to meet the new regulations if these start being built after June 2023.


New Rules in Scotland are Coming Soon

The Scottish Government has announced that it will legislate  before the end of 2022 to ensure developers provide electric vehicle (EV) charge points in the construction of new residential and non-residential buildings.  All new homes, including flats, with a dedicated car parking space are built with an electric charge point.

The details are outlined in the consultation response:

All new dwellings with a parking space are to have at least one EV charge point socket with minimum 7kW output power rating.  There is an exemption to requirement to install EV charge point if additional cost of electricity grid connection exceeds £2,000.  If exemption applies ducting infrastructure to be installed in each car parking space.


Wales 

An EV Charging Strategy for Wales published March 2021 proposes that new homes should be 'ready' for an EV charger - suggesting only cable provision, though this position looks weak compared to the positions taken by England and Scotland and I'd expect Wales to follow England and Scotland and require actual chargers are installed with an exemption if grid reinforcement costs are prohibitive.


Northern Ireland 

An EV Infrastructure Task-Force has been created to develop an EV Infrastructure Action Plan.  It's first meeting was December 2021.  Don't hold your breath on this one.



Friday, 15 July 2022

New Building Regulations for Scotland



In June 2022 the Scottish Government published its consultation response on changes to further tighten the Building Regulations for energy efficiency.  New developments in Scotland seeking a Building Warrant after 1 December 2022, will need to meet the new regulations.

Although most respondents to the consultation were in support of a higher performance target (delivering a 57% reduction in CO2 emissions), the government instead opted for the lower performance target which is expected to reduce the CO2 emissions of new homes in Scotland by 32%.

The central element of the building regulations for energy is the so-called 'Notional House Specification' which defines the target that a developer must meet. (For a full explanation of how the Notional House Specification works see this earlier blog).

The 2022 Building Regulations in Scotland gives three Notional House Specifications - one for homes heated with a heat pump, another for homes heated by a heat network and a third based on mains gas  for homes using any other heating systems.

The table below contrasts key elements of the new Notional House Specification with those in the previous version of Scottish Building Regulations and also with the new regulations that came into force in England this year.


As can be seen, the new Scottish Building regulations require a significant improvement in U-values (insulation) and airtightness compared to the current (2015) regulations.  They also come in slightly better than the latest regulations for England (it would have been a major surprise if they didn't!)

Of interest to solar industry participants will be the increase of PV provision in the gas heated notional house compared to the 2015 regulations.  

In 2015 Scotland became the first of the nations to add solar PV to the notional house - the amount asked for was the dwelling total floor area in m2 x 0.01kWp, which corresponds to 20Wp of solar per 1m2 of ground floor area (for a two storey building of equal ground and first floor areas).  The new requirement is for 0.4 x ground floor area in m2 / 6.5 -  which works out to be 62Wp of solar per 1m2 of ground floor area - around 3 times more solar per house.


Other Changes


Scottish Goverment also changed the way the benefits from solar are taken into account in the calculation.  The energy and carbon benefit of on-site generation is capped at the level assessed as being used on site (excluding the energy exported the grid).  This change is likely to incentivise the use of technologies to store excess solar energy for later use - for example battery storage or energy diverters that heat hot water with excess solar energy.


Good News for Solar?


The new regulations look like great news for solar in Scotland.  The Building Regulations are 'solution neutral' allowing developers to choose a combination of heating system, insulation and on-site generation that equals or exceeds the performance of the Notional House Specification.  Since both developers and house buyers prefer gas boilers to heat pumps, this regulation change is likely to increase the amount of solar installed on new homes in Scotland because of the three-fold increase in panel power in the specification.

However, the cloud on the horizon for the solar industry is another piece of legislation - the New Build Heating Standard, which will remove the gas boiler option for housebuilders by banning their use in new homes.  

Under these Building Regulations, once a housebuilder is forced to use heat pumps, the requirement for solar drops away because the Notional House Specification for heat pump heated homes does not include it.

Solar PV and heat pumps are a great match, with solar offsetting higher running costs of heat pumps - why would Scottish Government have no solar on the heat pump specification?  It all boils down to the cost for the developer - the regulations have been set up to encourage housebuilders to consider heat pumps before the 2024 regulations, and the notional house has been set up to try to level the playing field for build costs - leaving waste water heat recovery and solar off the heat pump specification.

No heed has been paid to the increased running costs the home owner will suffer in a heat pump heated home compared to a home with a gas boiler and solar PV.

Once there is a regulatory requirement in place to use a heat pump, then then the incentive to try to lower the cost of a heat pump installation versus gas plus solar falls away.  Scottish Government should commit to review the building regulations at the same time as bringing in its New Build Heat Standard to require solar PV on heat pump heated homes too.  This way it will ensure a just energy transition and reduce the risk of a consumer rejection of heat pumps.